Earthquake Resistant Design of Buildings | My Assignment Tutor

CVEN90017 Earthquake Resistant Design of BuildingsAssignment no.2Seismic Assessment of Reinforced Concrete WallsYear 2021(Due on Sunday 30th of May at 11:59 pm)students may work individually or in pairsConsider the floor plan of a multi-storey building in the next page. The structural engineer has designedthe gravity frame (i.e., beams, columns, and slabs), but has yet to design the reinforced concrete core toresist the lateral loads. It is assumed for this assignment that earthquake loading, rather than the loadingfrom wind, governs the design. Your task is to design a reinforced concrete core wall to resist theearthquake loading designed to AS 1170.4. You then need to calculate the displacement-capacity of thewall by first conducting a moment-curvature analysis (or sectional analysis), and conduct seismicassessment of the core walls using the capacity spectrum method. The following can be assumed for thebuilding:▪ The building has a total height (Hn) of 42 meters.▪ The building has 12 floors with an inter-storey height of 3.5 meters.▪ The building is designed for a superimposed dead load of 1 kPa and live load of 3 kPa. Thethickness of the slab is 240 mm, the self weight of other structural elements can be ignored inthe calculation of dead load.▪ It can be assumed that the building is torsionally-symmetrical and that higher mode effects donot need to be considered.▪ The wall geometry must fit within the area designated below in the floor plan.▪ The wall is assumed to be of uniform cross-section up the height of the structure.▪ It can be assumed that the “razor” columns do not contribute to the structure’s lateral stiffness▪ In conducting the moment-curvature analysis, you may assume axial load ratio of 5%Figure 1 Building Plan Layout with area for designed core wall/sTask no. 1Design a core wall to resist the lateral load determined from the Earthquake Loading AustralianStandard AS1170.4. You can assume the building is located in Melbourne (Z=0.08g) and 500 yrRP. The building is situated on Class D site conditions. You should make sure that the corewall/s have sufficient strength to resist the ground motions in both translational directions.Task no. 2The class has been trained on the use of EXCEL spreadsheets for undertaking analysis of themoment-curvature relationship of rectangular cross-sections. You are required to furtherdevelop and make use of your own designed spreadsheets for developing the moment-curvaturerelationships of the concrete cross-section at the base of the structural walls that you havedesigned. You are required to develop two curves, one curve with on an unconfined concretemodel and one with a confined concrete model.It is important that you undertake independent checks over the accuracies of the spreadsheetthat you have created. The checking may be accomplished by comparing results from softwarethat can be downloaded free from the internet. A well-known example of such software isRESPONSE-2000.You should determine the following with your EXCEL sectional-analyses program:▪ Curvature and moment at first yield (i.e., when the steel in the extreme tension fibreregion first reaches the yield strain)▪ Curvature and moment at ultimate (i.e., when the moment is at a maximum, or when thecompression strain reaches an ultimate unconfined strain of 0.003)The moment-curvature curve of the section can be plotted by investigating the moment andcurvature for different levels of reference strain up until failure. “Failure” is defined here aswhen the ultimate tension (εsu = 0.060) or compression (εcu = 0.003 or εcc = 0.010) strains arereached, or when a 20% drop in strength (i.e., moment) has occurred from its maximum. If thewall is non-rectangular, one-direction of bending can be assessed, rather than multiple (i.e., the“weaker” direction, or bending about the weaker [minor] axis, for example).Task no. 3Determine the displacement-capacity of the core wall/s. You should use the equations given inthe lecture for a plastic hinge analysis. Furthermore, you should also compare the displacementcapacity of the building with the following assumptions:▪ A single, primary crack forms and the equivalent plastic hinge length (Lp) is limited to asmall height at the base.▪ Secondary cracking occurs and the equivalent plastic hinge length (Lp) can form someheight up the wall from the base of the unconfined wall.▪ Secondary cracking occurs and the equivalent plastic hinge length (Lp) can form someheight up the wall from the base of the confined wall.Task no. 4Based on the three assumptions made in Task 3, assess if the building is safe under a very rareevent (2500 yr return period earthquake) on site class D site. You may use the capacityspectrum method to undertake the assessment. The acceleration displacement responsespectrum demand should be constructed based on site specific analysis using the MatLabprogram available in QuakeAdvice. The bore hole information can be downloaded from Canvas– Module – Assignment 2 Bore hole information.

QUALITY: 100% ORIGINAL PAPER – NO PLAGIARISM – CUSTOM PAPER

Leave a Reply

Your email address will not be published. Required fields are marked *